Enovation Controls offers a variety of highly reliable thermocouple and RTD (Resistance Temperature Detector) assemblies and 4-20 mA DC output RTD transmitters.
Their innovative features include a 304 stainless steel thermowell that provides protection to the spring-loaded element. The cast aluminum connecting head meets NEMA 4 requirements and includes an RTD transmitter or a thermocouple/ RTD terminal block mounted on ceramic Steatite and rated NEC Class 2. The complete assemblies are offered in 2-1/2, 4-1/2 or 7-1/2 in. (63, 114 or 191 mm) thermowell insertion lengths.
Additional product documentation can be found on our product support website or by clicking the Help Center button.
Thermocouple Assemblies with Thermowell
Available in types J or K, the thermocouple assemblies have ungrounded elements in a 304 stainless steel spring-loaded sheath. For product compatibility see next page (replacement parts and thermocouple extension wire are available).
RTD Assemblies with Thermowell
Resistance temperature detector (RTD) assemblies are available with a 100 ohm platinum element, 3-wire leads and spring-loaded 316L stainless steel element sheath.
RTD Transmitter Assemblies with Thermowell
RTDT assemblies transmit process variable temperatures. Available as part of the temperature sensor assemblies or as a separate units, the RTDTs accept 2- or 3-wire, 100 ohm RTDs. The RTD transmitters are loop powered. They feature linearized 4-20 mA DC outputs and have reversed polarity protection.
Model Number | Model and Description | Notes |
---|---|---|
Thermocouple Assemblies (thermowell included) | ||
TCJ-225 | J Type underground thermocouple, 1/2 NPT | 2-1/2 in. (63 mm) insertion length |
TCK-225 | K Type underground thermocouple, 1/2 NPT | |
TCJ-325 | J Type underground thermocouple, 3/4 NPT | |
TCK-325 | K Type underground thermocouple, 3/4 NPT | |
TCJ-245 | J Type underground thermocouple, 1/2 NPT | 4-1/2 in. (114 mm) insertion length |
TCK-245 | K Type underground thermocouple, 1/2 NPT | |
TCJ-345 | J Type underground thermocouple, 3/4 NPT | |
TCK-345 | K Type underground thermocouple, 3/4 NPT | |
TCJ-275 | J Type underground thermocouple, 1/2 NPT | 7-1/2 in. (191 mm) insertion length |
TCK-275 | K Type underground thermocouple, 1/2 NPT | |
TCJ-375 | J Type underground thermocouple, 3/4 NPT | |
TCK-375 | K Type underground thermocouple, 3/4 NPT | |
RTD Assemblies (thermowell included) | ||
RTD-225-400-100 | 100 ohm Pt RTD 400°F (204°C) max., 1/2 NPT | 2-1/2 in. (63 mm) insertion length |
RTD-325-400-100 | 100 ohm Pt RTD 400°F (204°C) max., 3/4 NPT | |
RTD-245-400-100 | 100 ohm Pt RTD 400°F (204°C) max., 1/2 NPT | 4-1/2 in. (114 mm) insertion length |
RTD-345-400-100 | 100 ohm Pt RTD 400°F (204°C) max., 3/4 NPT | |
RTD-275-400-100 | 100 ohm Pt RTD 400°F (204°C) max., 1/2 NPT | 7-1/2 in. (191 mm) insertion length |
RTD-375-400-100 | 100 ohm Pt RTD 400°F (204°C) max., 3/4 NPT | |
RTD Transmitter Assemblies (thermowell included) | ||
RTDT-225-400-100 | 100 ohm Pt 4-20 mA RTD Transmitter, 1/2 NPT, 0-400°F (-17.8-204°C) | 2-1/2 in. (63 mm) insertion length |
RTDT-225-140-100 | 100 ohm Pt 4-20 mA RTD Transmitter, 1/2 NPT, -60-140°F (-51.1-60°C) | |
RTDT-325-400-100 | 100 ohm Pt 4-20 mA RTD Transmitter, 3/4 NPT, 0-400°F (-17.8-204°C) | |
RTDT-325-140-100 | 100 ohm Pt 4-20 mA RTD Transmitter, 3/4 NPT, -60-140°F (-51.1-60°C) | |
RTDT-245-400-100 | 100 ohm Pt 4-20 mA RTD Transmitter, 1/2 NPT, 0-400°F (-17.8-204°C) | 4-1/2 in. (114 mm) insertion length |
RTDT-245-140-100 | 100 ohm Pt 4-20 mA RTD Transmitter, 1/2 NPT, -60-140°F (-51.1-60°C) | |
RTDT-345-400-100 | 100 ohm Pt 4-20 mA RTD Transmitter, 3/4 NPT, 0-400°F (-17.8-204°C) | |
RTDT-345-140-100 | 100 ohm Pt 4-20 mA RTD Transmitter, 3/4 NPT, -60-140°F (-51.1-60°C) | |
RTDT-275-400-100 | 100 ohm Pt 4-20 mA RTD Transmitter, 1/2 NPT, 0-400°F (-17.8-204°C) | 7-1/2 in. (191 mm) insertion length |
RTDT-275-140-100 | 100 ohm Pt 4-20 mA RTD Transmitter, 1/2 NPT, -60-140°F (-51.1-60°C) | |
RTDT-375-400-100 | 100 ohm Pt 4-20 mA RTD Transmitter, 3/4 NPT, 0-400°F (-17.8-204°C) | |
RTDT-375-140-100 | 100 ohm Pt 4-20 mA RTD Transmitter, 3/4 NPT, -60-140°F (-51.1-60°C) | |
Replacement Parts (order separately) | ||
TCHA | Cast aluminum head with terminal blocks for thermocouples | |
TCJE-25 | Type J elements only for 2-1/2 in wells* | all elements are spring loaded |
TCKE-25 | Type K elements only for 2-1/2 in wells* | |
TCJE-45 | Type J elements only for 4-1/2 in wells* | |
TCKE-45 | Type K elements only for 4-1/2 in wells* | |
TCJE-75 | Type J elements only for 7-1/2 in wells* | |
TCKE-75 | Type K elements only for 7-1/2 in wells* | |
PTW-225 | 1/2 NTP x 2-1/2 in. thermowell | |
PTW-325 | 3/4 NTP x 2-1/2 in. thermowell | |
PTW-245 | 1/2 NTP x 4-1/2 in. thermowell | |
PTW-345 | 3/4 NTP x 4-1/2 in. thermowell | |
PTW-275 | 1/2 NTP x 7-1/2 in. thermowell | |
PTW-375 | 3/4 NTP x 7-1/2 in. thermowell | |
RTDE-25 | 100 ohm Pt RTD element only for 2-1/2 in. wells | all elements are spring loaded |
RTDE-45 | 100 ohm Pt RTD element only for 4-1/2 in. wells | |
RTDE-75 | 100 ohm Pt RTD element only for 7-1/2 in. wells | |
RTDTX-400-100 | 100 ohm Pt RTD Transmitter only 0-400°F (-17.8-204°C) | |
RTDTX-140-100 | 100 ohm Pt RTD Transmitter only -60-140°F (-51.1-60°C) | |
Thermocouple Extension Wire | ||
00003271 | Type J 100 ft. roll | |
00003272 | Type K 100 ft. roll |