ItemDRC
Supply Voltage9 to 32VDC
Supply CurrentIsol + 50mA
Output Current"-06A" 600mA or "-12A" 1.2A or "-25A" 2.5A Maximum
Solenoid Resistance2 Ohms Minimum
Reference Voltages-10V, +10V @ 20mA
Dither Settings30, 50, 75, 100, 125, 150, 175, 200, 225, 250, 275, 300, 1000 Hz
Analog Input Range"DRC-Vxx"  -10 to 10V, "DRC-Axx" 0 to 20mA
Analog Input Impedance"DRC-Vxx" 38 K Ohms, "DRC-Axx" 250 Ohm
Operating Temperature Range-20 to +70 Deg. C
EnclosurePolyamide
DimensionsInch: 0.69 W x 4.50 H x 4.30 D mm: 17.5 W x 114.5 H x 109.4 D
ItemDRF
Supply Voltage9 to 32VDC
Supply CurrentIsol + 50mA
Output Current"-06A" 600mA or "-12A" 1.2A or "-25A" 2.5A Max.
Solenoid Resistance2 Ohms Minimum
Reference Voltages-10V, +10V @ 20mA
Dither Settings30, 50, 75, 100, 125, 150, 175, 200, 225, 250, 275, 300, 1000 Hz
Analog Input Range"DRF-Vxx"  -10 to 10V, "DRF-Axx" 0 to 20mA
Analog Input Impedance"DRF-Vxx" 38 K Ohms, "DRF-Axx" 250 Ohm
Analog Input Resolution10 bits
Operating Temperature Range-20 to +70 Deg. C
EnclosurePolyamide
DimensionsInch: 0.69 W x 4.50 H x 4.30 D mm: 17.5 W x 114.5 H x 109.4 D

WARNING: This product can expose you to chemicals including lead, which are known to the State of California to cause cancer, birth defects or other reproductive harm. For more information about California Propsition 65, go to www.P65Warnings.ca.gov or visit our California Proposition 65 page.

Backup Method - Rich Text: 

DRC PART NUMBERS:

Description

DRCx

-Input

Output

1 Output Channel

1

-

-

2 Output Channel

2

-

-

4 Output Channel

4

-

-

Voltage Input -10V to +10V

 

V

-

Current Input 0 to 20mA

 

A

-

600mA Output

 

 

06

1.2A Output

 

 

12

2.5A Output

 

 

25

Example: DRC4-V06 is a 4 channel, voltage input, 600mA outputs.

DRF PART NUMBERS:

Description

DRFx

-Input

Output

2 Input/Output Channels

2

-

-

4 Input/Output Channels

4

-

-

Voltage Input -10V to +10V

 

V

-

Current Input 0 to 20mA

 

A

-

600mA Output

 

 

06

1.2A Output

 

 

12

2.5A Output

 

 

25